NXdata

Status:

base class, extends NXobject

Description:

NXdata describes the plottable data and related dimension scales.

It is strongly recommended that there is at least one NXdata group in each NXentry group. Note that the fields named VARIABLE and DATA can be defined with different names. (Upper case is used to indicate that the actual name is left to the user.) The signal and axes attributes of the data group define which items are plottable data and which are dimension scales, respectively.

NXdata is used to implement one of the basic motivations in NeXus, to provide a default plot for the data of this NXentry. The actual data might be stored in another group and (hard) linked to the NXdata group.

  • Each NXdata group will define one field as the default plottable data. The value of the signal attribute names this field. Additional fields may be used to describe the dimension scales and uncertainities. The auxiliary_signals attribute is a list of the other fields to be plotted with the signal data.

  • The plottable data may be of arbitrary rank up to a maximum of NX_MAXRANK=32 (for compatibility with backend file formats).

  • The plottable data will be named as the value of the group signal attribute, such as:

    data:NXdata
      @signal = "counts"
      @axes = "mr"
      @mr_indices = 0
      counts: float[100]  --> the default dependent data
      mr: float[100]  --> the default independent data
    

    The field named in the signal attribute must exist, either directly as a NeXus field or defined through a link.

  • The group axes attribute will name the dimension scale associated with the plottable data.

If available, the standard deviations of the data are to be stored in a data set of the same rank and dimensions, with the name errors.

  • For each data dimension, there should be a one-dimensional array of the same length.

  • These one-dimensional arrays are the dimension scales of the data, i.e. the values of the independent variables at which the data is measured, such as scattering angle or energy transfer.

The preferred method to associate each data dimension with its respective dimension scale is to specify the field name of each dimension scale in the group axes attribute as a string list. Here is an example for a 2-D data set data plotted against time, and pressure. (An additional temperature data set is provided and could be selected as an alternate for the pressure axis.):

data_2d:NXdata
  @signal="data"
  @axes=["time", "pressure"]
  @pressure_indices=1
  @temperature_indices=1
  @time_indices=0
  data: float[1000,20]
  pressure: float[20]
  temperature: float[20]
  time: float[1000]

Old methods to identify the plottable data

There are two older methods of associating each data dimension to its respective dimension scale. Both are now out of date and should not be used when writing new data files. However, client software should expect to see data files written with any of these methods.

  • One method uses the axes attribute to specify the names of each dimension scale.

  • The oldest method uses the axis attribute on each dimension scale to identify with an integer the axis whose value is the number of the dimension.

Each axis of the plot may be labeled with information from the dimension scale for that axis. The optional @long_name attribute is provided as the axis label default. If @long_name is not defined, then use the name of the dimension scale. A @units attribute, if available, may be added to the axis label for further description. See the section NeXus Data Units for more information.

The optional title field, if available, provides a suggested title for the plot. If no title field is found in the NXdata group, look for a title field in the parent NXentry group, with a fallback to displaying the path to the NXdata group.

NeXus is about how to find and annotate the data to be plotted but not to describe how the data is to be plotted. (https://www.nexusformat.org/NIAC2018Minutes.html#nxdata-plottype–attribute)

Symbols:

These symbols will be used below to coordinate fields with the same shape.

dataRank: rank of the DATA field

n: length of the VARIABLE field

nx: length of the x field

ny: length of the y field

nz: length of the z field

Groups cited:

none

Structure:

@auxiliary_signals: (optional) NX_CHAR

Array of strings holding the names of additional signals to be plotted with the default signal (specified by the signal attribute). Each auxiliary signal needs to be of the same shape as the default signal.

@signal: (optional) NX_CHAR

Declares which NeXus field is the default. The value is the name of the NeXus field to be plotted. (The value names an existing child of this group. The child group must itself be a NeXus group.)

It is recommended (as of NIAC2014) to use this attribute rather than adding a signal attribute to the field. See https://www.nexusformat.org/2014_How_to_find_default_data.html for a summary of the discussion.

@axes: (optional) NX_CHAR

String array that defines the independent data fields used in the default plot for all of the dimensions of the signal field (the signal field is the field in this group that is named by the signal attribute of this group). One entry is provided for every dimension in the signal field.

The field(s) named as values (known as “axes”) of this attribute must exist. An axis slice is specified using a field named AXISNAME_indices as described below (where the text shown here as AXISNAME is to be replaced by the actual field name).

When no default axis is available for a particular dimension of the plottable data, use a “.” in that position. Such as:

@axes=["time", ".", "."]

Since there are three items in the list, the the signal field must must be a three-dimensional array (rank=3). The first dimension is described by the values of a one-dimensional array named time while the other two dimensions have no fields to be used as dimension scales.

See examples provided on the NeXus wiki: https://www.nexusformat.org/2014_axes_and_uncertainties.html

If there are no axes at all (such as with a stack of images), the axes attribute can be omitted.

@AXISNAME_indices: (optional) NX_INT

Each AXISNAME_indices attribute indicates the dependency relationship of the AXISNAME field (where AXISNAME is the name of a field that exists in this NXdata group) with one or more dimensions of the plottable data.

Integer array that defines the indices of the signal field (that field will be a multidimensional array) which need to be used in the AXISNAME field in order to reference the corresponding axis value.

The first index of an array is 0 (zero).

Here, AXISNAME is to be replaced by the name of each field described in the axes attribute. An example with 2-D data, \(d(t,P)\), will illustrate:

data_2d:NXdata
  @signal="data"
  @axes=["time", "pressure"]
  @time_indices=0
  @pressure_indices=1
  data: float[1000,20]
  time: float[1000]
  pressure: float[20]

This attribute is to be provided in all situations. However, if the indices attributes are missing (such as for data files written before this specification), file readers are encouraged to make their best efforts to plot the data. Thus the implementation of the AXISNAME_indices attribute is based on the model of “strict writer, liberal reader”.

Note

Attributes potentially containing multiple values (axes and _indices) are to be written as string or integer arrays, to avoid string parsing in reading applications.

VARIABLE: (optional) NX_NUMBER (Rank: 1, Dimensions: [n])

Dimension scale defining an axis of the data. Client is responsible for defining the dimensions of the data. The name of this field may be changed to fit the circumstances. Standard NeXus client tools will use the attributes to determine how to use this field.

@long_name: (optional) NX_CHAR

Axis label

@distribution: (optional) NX_BOOLEAN

0|false: single value, 1|true: multiple values

@first_good: (optional) NX_INT

Index of first good value

@last_good: (optional) NX_INT

Index of last good value

@axis: (optional) NX_POSINT

Index (positive integer) identifying this specific set of numbers.

N.B. The axis attribute is the old way of designating a link. Do not use the axes attribute with the axis attribute. The axes group attribute is now preferred.

VARIABLE_errors: (optional) NX_NUMBER (Rank: 1, Dimensions: [n])

“Errors” (actually uncertainties) associated with axis VARIABLE. Client is responsible for defining the dimensions of the data. The name of this field may be changed to fit the circumstances but is matched with the VARIABLE field with _errors appended.

This pattern of using VARIABLE_errors can be used throughout a NeXus data file to associate uncertainties with a field named VARIABLE. This pattern also applies to other relationships such as VARIABLE_resolutions to connect additional data with a certain field.

DATA: (optional) NX_NUMBER (Rank: dataRank)

This field contains the data values to be used as the NeXus plottable data. Client is responsible for defining the dimensions of the data. The name of this field may be changed to fit the circumstances. Standard NeXus client tools will use the attributes to determine how to use this field.

@signal: (optional) NX_POSINT

Plottable (independent) axis, indicate index number. Only one field in a NXdata group may have the signal=1 attribute. Do not use the signal attribute with the axis attribute.

@axes: (optional) NX_CHAR

Defines the names of the dimension scales (independent axes) for this data set as a colon-delimited array. NOTE: The axes attribute is the preferred method of designating a link. Do not use the axes attribute with the axis attribute.

@long_name: (optional) NX_CHAR

data label

errors: (optional) NX_NUMBER (Rank: dataRank)

Standard deviations of data values - the data array is identified by the group attribute signal. The errors array must have the same dimensions as data. Client is responsible for defining the dimensions of the data.

scaling_factor: (optional) NX_FLOAT

The elements in data are usually float values really. For efficiency reasons these are usually stored as integers after scaling with a scale factor. This value is the scale factor. It is required to get the actual physical value, when necessary.

offset: (optional) NX_FLOAT

An optional offset to apply to the values in data.

title: (optional) NX_CHAR

Title for the plot.

x: (optional) NX_FLOAT (Rank: 1, Dimensions: [nx]) {units=NX_ANY}

This is an array holding the values to use for the x-axis of data. The units must be appropriate for the measurement.

y: (optional) NX_FLOAT (Rank: 1, Dimensions: [ny]) {units=NX_ANY}

This is an array holding the values to use for the y-axis of data. The units must be appropriate for the measurement.

z: (optional) NX_FLOAT (Rank: 1, Dimensions: [nz]) {units=NX_ANY}

This is an array holding the values to use for the z-axis of data. The units must be appropriate for the measurement.

Hypertext Anchors

List of hypertext anchors for all groups, fields, attributes, and links defined in this class.

NXDL Source: